Exam2pass
0 items Sign In or Register
  • Home
  • IT Exams
  • Guarantee
  • FAQs
  • Reviews
  • Contact Us
  • Demo
Exam2pass > Dell > Dell Certifications > D-UN-DY-23 > D-UN-DY-23 Online Practice Questions and Answers

D-UN-DY-23 Online Practice Questions and Answers

Questions 4

A storage engineer must grant access of a Dell Unity XT provisioned NFS datastore to ESXi-1.dell.local. The NAS server used to create the datastore is configured for NFSv4 protocol with Kerberos NFS owner authentication.

Which permission level is required for the ESXi host?

A. Read/write

B. Read-only

C. Read/write, enable Root

Buy Now

Correct Answer: C

To grant access of a Dell Unity XT provisioned NFS datastore to an ESXi host, the permission level required for the host depends on the NFS protocol and authentication method used by the NAS server. For NFSv4 with Kerberos NFS owner

authentication, the ESXi host must have the Read/write, enable Root permission level. This allows the ESXi host to read and write data to the datastore, as well as perform administrative tasks such as creating and deleting virtual machines.

The Read/write permission level alone is not sufficient, as it does not allow the ESXihost to perform root- level operations on the datastore. The Read-only permission level only allows the ESXi host to read data from the datastore, but not

write or modify it. References: Dell EMC Unity:

Configuring hosts to access NFS1, page 9.

Questions 5

A company has an ESXi host installed with FC HBAs that is connected to a Dell Unity XT storage array. A 500 GB LUN is provisioned to this host from the Unity array and is in production. The VMware administrator has configured a new vSwitch with the NICs on the server intended for iSCSI traffic. The storage administrator is asked to configure software iSCSI and provision a new 1 TB LUN from the storage array using iSCSI.

What is a consideration when satisfying this request?

A. Two iSCSI target interfaces must be configured with IP addresses from separate subnets.

B. Any single host should connect to any single array using one protocol only.

C. A connection must be established between the host iSCSI initiators and Unity iSCSI targets before provisioning the new LUN.

Buy Now

Correct Answer: B

Mixing FC and iSCSI protocols for the same host and array is not supported by Dell EMC Unity. This can cause issues with multipathing, failover, and performance. The best practice is to use one protocol per host and array pair. If the host needs to access both FC and iSCSI LUNs from different arrays, then separate vSwitches and port groups should be used for each protocol. References: Dell EMC Unity: Best Practices Guide1, page 19.

Questions 6

A storage administrator must configure replication from a production Dell Unity XT 680F to an offsite DR Dell Unity XT 480. Block resources must be replicated without data loss if the production site becomes unavailable. File resources can

be replicated with an acceptable amount of data difference on the destination.

What replication configuration meets the requirements?

A. Set Unisphere resource filtering to All.

B. Configure the replication connection mode to Both.

C. Set an RPO of 0 on the synchronous replication sessions.

D. Configure the replication interfaces on the 4-port mezzanine card.

Buy Now

Correct Answer: B

To meet the requirements, the replication connection mode must be set to Both, which allows both synchronous and asynchronous replication sessions to be configured on the same connection. This way, block resources can use synchronous replication, which ensures zero data loss, and file resources can use asynchronous replication, which allows some data difference on the destination. Setting Unisphere resource filtering to All is not necessary, as it only affects the display of resources in the Unisphere GUI. Setting an RPO of 0 on the synchronous replication sessions is redundant, as synchronous replication always has an RPO of 0. Configuring the replication interfaces on the 4-port mezzanine card is not relevant, as it only affects the performance and availability of the replication network. References: [Dell EMC Unity: Replication Technologies], [Dell EMC Unity: Unisphere Overview]

Questions 7

An administrator has configured a Host Group to have access to a storage object.

What are two benefits of this configuration? (Choose two.)

A. Ensures that snapshots are applied to all LUNs in the group

B. Provides multiple hosts the same access to NFS Filesvstems

C. Provides multiple hosts access to the same VMFS Datastores

D. Ensures that block storage is replicated to the same hosts

E. Provides multiple hosts access to the same LUNs

Buy Now

Correct Answer: CE

A Host Group is a logical grouping of hosts that share the same access permissions to storage objects, such as LUNs, VMFS Datastores, or NFS Filesystems. By configuring a Host Group, an administrator can simplify the management of multiple hosts and ensure consistent access to the storage resources. Some of the benefits of using a Host Group are: Provides multiple hosts access to the same VMFS Datastores: A VMFS Datastore is a block-based storage object that is formatted with the VMware File System (VMFS) and used to store virtual machine files. A VMFS Datastore can be shared by multiple hosts that are part of a VMware cluster. By adding these hosts to a Host Group and assigning the VMFS Datastore to the Host Group, the administrator can ensure that all the hosts have the same access permissions and can access the virtual machines on the Datastore. Provides multiple hosts access to the same LUNs: A LUN is a block-based storage object that is presented to a host as a SCSI device. A LUN can be shared by multiple hosts that have the same operating system and use a cluster-aware file system. By adding these hosts to a Host Group and assigning the LUN to the Host Group, the administrator can ensure that all the hosts have the same access permissions and can access the data on the LUN. References: Dell EMC Unity: Host Configuration Dell EMC Unity: VMware ESXi Hosts and Clusters

Questions 8

Which I/O modules does the Unity 380/380F system support?

A. 12 Gb/s SAS 2-Port 100 GbE

B. 32 Gb/s Fibre Channel 10 GbE Base-T

C. 12 Gb/s SAS 10 GbE Base-T

D. 32 Gb/s Fibre Channel 2-Port 100 GbE

Buy Now

Correct Answer: C

The Unity 380/380F system supports two types of I/O modules: 12 Gb/s SAS back-end and 10 GbE Base-T front-end. The 12 Gb/s SAS back-end module provides connectivity to the disk drives and expansion enclosures, while the 10 GbE Base-T front- end module provides network connectivity to the hosts and clients. The Unity 380/380F system has four I/O module slots, two for each SP. The 12 Gb/s SAS back-end module must be installed in slot 0 of each SP, and the 10 GbE Base-T front-end module can be installed in slot 1 of each SP. Therefore, the correct answer is C References: Dell EMC Unity: Hardware Information Guide Dell EMC Unity: Installation Guide

Questions 9

A deployment engineer has changed theSchedule Time Zoneunder the Settings menu. However, existing snapshots schedules continue to run at the previously configured time.

Why is this occurring?

A. Existing snapshot schedules cannot be updated to the same absolute time.

B. The Unity system time is not set correctly and must be updated under system settings.

C. Existing snapshot schedules are not updated to the same absolute time when the time zone is changed.

D. The Unity management server was not restarted before time zone changes took effect.

Buy Now

Correct Answer: C

When the Schedule Time Zone is changed under the Settings menu, it only affects the display of the time zone and the creation of new snapshot schedules. Existing snapshot schedules are not automatically adjusted to the new time zone, and will continue to run at the same absolute time as before. For example, if a snapshot schedule was created to run every day at 10:00 AM inGMT+1, and the Schedule Time Zone was changed to GMT+2, the snapshot schedule will still run at 10:00 AM in GMT+1, which is

11:00 AM in GMT+2. To update the existing snapshot schedules to the new time zone, the administrator must edit each schedule manually and change the start time accordingly. References: Dell EMC Unity: Snapshots and Thin Clones1, page 16.

Questions 10

What is a characteristic of FAST VP?

A. Fast VP data relocation runs in the background at all times once it is enabled.

B. Fast VP optimizes data replacement by moving 1 GB slices between disk tiers.

C. Users can set the Fast VP data relocation rate.

D. Users can enable or disable FAST VP at the LUN level.

Buy Now

Correct Answer: C

FAST VP (Fully Automated Storage Tiering for Virtual Pools) is a feature that automatically moves data within a storage pool based on the performance requirements and access patterns of the data. FAST VP data relocation runs in the background according to a user-defined schedule and rate. The schedule determines when the data relocation starts and ends, and the rate determines how much system resources are used for the data relocation. Users can set the Fast VP data relocation rate to High, Medium, Low, or None. High means that the data relocation has the highest priority and uses the most system resources, while None means that the data relocation is disabled. Fast VP data relocation does not run at all times, but only during the scheduled window. Fast VP optimizes data placement by moving 256 MB slices between disk tiers, not 1 GB slices. Users cannot enable or disable FAST VP at the LUN level, but only at the storage pool level. References: [Dell EMC Unity: FAST Technology Overview], [Dell EMC Unity: Storage Pools and RAID Groups]

Questions 11

What is the result of enabling Data Reduction on a LUN in a consistency group containing three LUNs?

A. Any writes to the LUN will go through the Data Reduction logic.

B. Data Reduction and Advanced Deduplication will be enabled on all LUNs.

C. Data Reduction will be enabled on all LUNs is the consistency group.

D. All writes to all consistency group LUNs will go through the Data Reduction logic.

Buy Now

Correct Answer: D

Data Reduction is a feature that reduces the amount of physical storage space required to store user data on a LUN. Data Reduction is enabled at the LUN level and applies to all the data in the LUN, including snapshots and thin clones. Data Reduction consists of two components: compression and deduplication. Compression reduces the size of data blocks by removing redundant information, while deduplication eliminates duplicate blocks across the LUN. When Data Reduction is enabled on a LUN, all writes to the LUN will go through the Data Reduction logic before being written to the storage pool. If the LUN is part of a consistency group, Data Reduction will be enabled on all the LUNs in the consistency group, and all writes to any LUN in the group will go through the Data Reduction logic. This ensures that the data in the consistency group is consistent and protected by the same Data Reduction settings. References: Dell EMC Unity: Data Reduction Overview Dell EMC Unity: Data Reduction Configuration and Best Practices

Questions 12

What is the maximum number of drives on a traditional RAID Group?

A. 64 drives

B. 16 drives

C. 8 drives

D. 32 drives

Buy Now

Correct Answer: B

Questions 13

Which two actions are recommended according to best practices when connecting iSCSI host to a Dell Unity XT system? (Choose two.)

A. Manually register host on storage array.

B. Use standard NIC for iSCSI.

C. Interfaces should be on separate subnets.

D. Use private network for iSCSI interfaces.

Buy Now

Correct Answer: CD

Two actions that are recommended according to best practices when connecting iSCSI host to a Dell Unity XT system are to ensure that the interfaces are on separate subnets and to use a private network for iSCSI interfaces. These actions can improve the performance, security, and availability of the iSCSI network. Having interfaces on separate subnets can prevent broadcast storms, reduce network congestion, and enable multipathing. Using a private network for iSCSI interfaces can isolate the iSCSI traffic from other network traffic, reduce the risk of interference or attacks, and simplify the network configuration. Manually registering host on storage array and using standard NIC for iSCSI are not recommended actions, as they can introduce errors, inefficiencies, and limitations. References: [Dell EMC Unity: iSCSI Configuration], [Dell EMC Unity: Best Practices Guide]

Exam Code: D-UN-DY-23
Exam Name: Dell Unity Deploy 2023
Last Update: Jun 09, 2025
Questions: 36

PDF (Q&A)

$45.99
ADD TO CART

VCE

$49.99
ADD TO CART

PDF + VCE

$59.99
ADD TO CART

Exam2Pass----The Most Reliable Exam Preparation Assistance

There are tens of thousands of certification exam dumps provided on the internet. And how to choose the most reliable one among them is the first problem one certification candidate should face. Exam2Pass provide a shot cut to pass the exam and get the certification. If you need help on any questions or any Exam2Pass exam PDF and VCE simulators, customer support team is ready to help at any time when required.

Home | Guarantee & Policy |  Privacy & Policy |  Terms & Conditions |  How to buy |  FAQs |  About Us |  Contact Us |  Demo |  Reviews

2025 Copyright @ exam2pass.com All trademarks are the property of their respective vendors. We are not associated with any of them.