A server administrator needs to expand a VMware vSphere farm and use an already existing server profile as a baseline. Click the area where new server profile templates can be created from a selected server profile.
Hot Area:

Match the minimum HPE OneView license required to each function. (Matches may be used more than once.)
Select and Place:

Refer to the exhibit.

An administrator is creating new volumes in preparation for a new Hyper-V cluster. On the Create Volume screen, the storage administrator notices that the capacity of the volume can't be edited. What is preventing the administrator from increasing the volume size?
A. The capacity is a locked value in the volume template.
B. The storage pool is out of capacity, so no additional storage can be allocated.
C. The wrong storage system is selected.
D. The administrator doesn't have permissions to create volumes.
Refer to the exhibit.

A server administrator using the REST API is troubleshooting the error seen in the exhibit. What needs to be fixed in the command?
A. add the missing authentication token to the header
B. change http to https in the URL
C. change the "login-sessions" string in the URL to "login-session"
D. change the POST method to PUT
What are benefits of using HPE OneView along with 3rd Party integrations? (Choose two.)
A. Extensive management of 3rd Party server and storage devices
B. Faster application development
C. Integrated management of 3rd Party software licenses
D. Standardized templates to optimize industry standard applications
E. Simplified infrastructure lifecycle operations
Which listed HPE OneView integration points are available within System Center with the HPE OneView Advanced License? (Choose two.)
A. Service Manager
B. Azure Resource Manager
C. Operations Manager
D. Data Protection Manager
E. Virtual Machine Manager
After assigning a server profile to an HPE ProLiant blade, you notice that the serial number being reported on the server profile page is not the one that matches the label on the server. You want the reported serial number to match the label. What do you need to do?
A. Create a new Server Profile and go to the "Advanced" section, then change the radio button for the serial number/UUID from "Virtual" to "Physical" and apply it to the server.
B. Edit the Server Profile and go to the "Advanced" section, then change the radio button for serial number/UUID from "Virtual" to "Physical".
C. Create a new Server Profile Template and go to the "Advanced" section, then change the radio button for the serial number/UUID from "Virtual" to "Physical".
D. Edit the Server Profile and go to the "Advanced" section, then change the radio button for serial number/ UUID from "Virtual" to "Physical" and enter the serial number.
A server administrator wants to prevent excessive unknown destination frames from affecting the network performance of Synergy compute modules. Which HPE OneView setting at the Logical Interconnect Group level can help?
A. storm control
B. loop protection
C. SNMPv3
D. IGMP snooping
What is the most likely reason for CPU, temperature, or power utilization not being presented in HPE OneView?
A. The agent on the server stopped communicating with HPE OneView.
B. The wrong SNMP data was entered into iLO.
C. The wrong HPE OneView Advanced License Key was entered.
D. The server doesn't have an iLO Advanced License.